Trench Technology
Katherm QK
Article no.:
14241113324324
Overview
- All factory-fitted components are wired to terminals
- Compact connecting terminal strip
- Convenient/space-saving connection area
- Power supply via on-site power supply components
- Control by Kampmann room thermostats or on-site controls
The long fans installed in Katherm QK units ensure an even air flow through the coil. This also ensures greater comfort and a directed air outlet from the trench.The long fans installed in Katherm QK units ensure an even air flow through the coil. This also ensures greater comfort and a directed air outlet from the trench.
- For fast connection
- Saves installation time
- Optional valves (accessories)
- For quick and safe electrical connection
- Saves installation time
- For control options: KaControl, -C1 and 230 V electromechanical --00
- Including 230/24 V power unit
- Removable end panel for ease of connection of trenches
- As visual cover and protection against dirt ingress
- A proven combination of copper/aluminium
- Optimised for air flow and heat dissipation
- Painted graphite-grey
Treated supply air can be fed into rooms through the Katherm supply air module (Length 400 mm)
Calculate performance data
Sound power octave spectrum
The sound power is determined depending on the use according to DIN EN ISO 3741 (in the echo chamber), according to DIN EN ISO 3744 (in the low-reflective half-space) or according to DIN EN ISO 9614 (intensity method).
Oktave Spektrum
EPD data
Item number-specific LCA data based on verified EPD according to EN 15804, which is available for download at The International EPD System. Separate subdivision of life cycle modules available online via button "EPD data sheet". The environmental impacts of module B refer to 1 year of operation. A: Product and construction process stage - B: Use stage - C: End of life stage - D: Benefits and loads beyond the system boundary
Impact Category | A | B | C | D |
---|---|---|---|---|
GWP - Fossil | kg CO₂ eq | 1.12E+02 | 8.07E+00 | 3.67E+00 | -4.36E+01 |
GWP - Biogenic | kg CO₂ eq | -2.23E+00 | 8.73E-01 | 1.47E-03 | -3.33E-02 |
GWP - Luluc | kg CO₂ eq | 6.53E-01 | 4.40E-02 | 1.91E-04 | -3.61E-01 |
GWP - Total | kg CO₂ eq | 1.11E+02 | 8.98E+00 | 3.67E+00 | -4.39E+01 |
ODP | kg CFC-11 eq | 6.30E-06 | 5.68E-07 | 7.57E-08 | -3.06E-06 |
AP | mol H+ eq | 1.02E+00 | 6.44E-02 | 1.54E-03 | -5.27E-01 |
EP - Freshwater | kg P eq | 8.34E-02 | 4.48E-03 | 4.96E-05 | -4.47E-02 |
EP - Marine | kg N eq | 2.17E-01 | 1.71E-02 | 5.23E-04 | -4.92E-02 |
EP - Terrestrial | mol N eq | 1.37E+00 | 9.06E-02 | 5.49E-03 | -5.62E-01 |
POCP | kg NMVOC | 4.10E-01 | 2.17E-02 | 1.32E-03 | -1.66E-01 |
ADPE | kg Sb eq | 1.28E-02 | 9.60E-04 | 1.21E-06 | -8.47E-03 |
ADPF | MJ | 1.41E+03 | 1.94E+02 | 3.82E+00 | -5.44E+02 |
WDP | m³ depriv. | 3.12E+01 | 1.35E+00 | 1.16E-01 | -7.67E+00 |
PM | disease inc. | 8.48E-06 | 2.48E-07 | 2.36E-08 | -3.15E-06 |
IR | kBq U-235 eq | 1.34E+01 | 6.50E+00 | 2.23E-02 | -5.03E+00 |
ETP - FW | CTUe | 5.89E+03 | 4.55E+02 | 1.59E+01 | -3.72E+03 |
HTP - C | CTUh | 6.33E-07 | 1.41E-08 | 5.86E-10 | -2.29E-07 |
HTP - NC | CTUh | 9.00E-06 | 6.01E-07 | 8.36E-09 | -5.73E-06 |
SQP | Pt | 9.43E+02 | 9.51E+01 | 5.42E+00 | -2.12E+02 |
PERE | MJ | 3.24E+02 | 3.72E+01 | 1.30E-01 | -1.10E+02 |
PERM | MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
PERT | MJ | 3.24E+02 | 3.72E+01 | 1.30E-01 | -1.10E+02 |
PENRE | MJ | 1.41E+03 | 1.94E+02 | 3.82E+00 | -5.44E+02 |
PENRM | MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
PENRT | MJ | 1.41E+03 | 1.94E+02 | 3.82E+00 | -5.44E+02 |
SM | kg | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
RSF | MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
NRSF | MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
FW | m³ | 7.13E-01 | 8.59E-02 | 3.70E-03 | -2.71E-01 |
HWD | kg | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
NHWD | kg | 5.23E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
RWD | kg | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
CRU | kg | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
MFR | kg | 0.00E+00 | 0.00E+00 | 1.59E+01 | 0.00E+00 |
MER | kg | 0.00E+00 | 0.00E+00 | 1.30E+00 | 0.00E+00 |
EE (Electrical) | MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
EE (Thermal) | MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
*GWP-GHG | kg CO₂ eq | 1.11E+02 | 8.01E+00 | 3.67E+00 | -4.23E+01 |
Accessories
Control accessories electromechanical 24 V
Clock thermostat
Heating/Cooling, 2- and 4-pipe, continuously variable, with LCD operating menu and integrated timer program, heating/cooling changeover by means of external potential-free contact (low voltage), 24 V Actuator, Open/Closed, 1 W, flush-mounted, Protection class IP 30, Colour similar to RAL 9010 pure white, Type 30456
Only in conjunction with valves/valve kits!
optional connectible, remote sensor art. no. 196000148921
can optionally be connected, clip-on sensor art. no. 196000148922
Suitable for: EC units, electromechanical 24 V/230 V, 5 Katherm HK, Katherm HK 320 E, Katherm QK or Katherm QK nano Trench Technology, 5 PowerKon nano Perimeter Heating
Only in conjunction with valves/valve kits!
optional connectible, remote sensor art. no. 196000148921
can optionally be connected, clip-on sensor art. no. 196000148922
Suitable for: EC units, electromechanical 24 V/230 V, 5 Katherm HK, Katherm HK 320 E, Katherm QK or Katherm QK nano Trench Technology, 5 PowerKon nano Perimeter Heating
Article no.:
196000030456
Power supply unit
for external installation outside the trench heater, 85 - 264 V AC, 24 V DC, 36 W, on DIN rail, Protection class II
Suitable for: EC units, electromechanical 24 V, 1 Katherm QK Trench Technology, 3 Katherm QK nano Trench Technology, 3 PowerKon nano Perimeter Heating
Suitable for: EC units, electromechanical 24 V, 1 Katherm QK Trench Technology, 3 Katherm QK nano Trench Technology, 3 PowerKon nano Perimeter Heating
Article no.:
196901335152
Power supply unit
for external installation outside the trench heater, 86 - 264 V AC, 24 V DC, 47 Hz, 60 W, on DIN rail, Protection class II
Suitable for: EC units, electromechanical 24 V, 2 Katherm QK Trench Technology, 5 Katherm QK nano Trench Technology, 6 PowerKon nano Perimeter Heating
Suitable for: EC units, electromechanical 24 V, 2 Katherm QK Trench Technology, 5 Katherm QK nano Trench Technology, 6 PowerKon nano Perimeter Heating
Article no.:
196901338401
Power supply unit
for external installation outside the trench heater, 86 - 264 V AC, 24 V DC, 47 Hz, 92 W, on DIN rail, Protection class II
Suitable for: EC units, electromechanical 24 V, 4 Katherm QK Trench Technology, 7 Katherm QK nano Trench Technology, 10 PowerKon nano Perimeter Heating
Suitable for: EC units, electromechanical 24 V, 4 Katherm QK Trench Technology, 7 Katherm QK nano Trench Technology, 10 PowerKon nano Perimeter Heating
Article no.:
196901338402
Valve kits
Valve kit
includes 1 no. pre-settable valve body, straight, 1 no. thermoelectric actuator 24 V, 1 no. return shut-off valve, straight, 24 V actuator, Connection 1/2''
Article no.:
194000142110
Valves and return shut-off valves
Valve body
straight, pre-settable, Connection 1/2'', kvs value 1 m³/h, Max. operating pressure 10 bar
Suitable for: Katherm NK 182 (trench heights 150 mm and 200 mm), Katherm NK 232/300/380 (all trench heights), DN 15
Suitable for: Katherm NK 182 (trench heights 150 mm and 200 mm), Katherm NK 232/300/380 (all trench heights), DN 15
Article no.:
194000346909
Pre-setting key
Once per project necessary.
Suitable for: pre-settable valve bodies, valve kits and convector connection kit
Suitable for: pre-settable valve bodies, valve kits and convector connection kit
Article no.:
194000346915
Return shut-off valve
Straight, Connection 1/2''
Article no.:
194000145952
Valve actuators
Thermoelectric actuator
24 V AC/DC
Suitable for: Katherm, control configuration KaControl -C1 and clock thermostat type 30456
Suitable for: Katherm, control configuration KaControl -C1 and clock thermostat type 30456
Article no.:
194000146906
Mitred corners
Mitred corner
Roll-up grille Aluminium, natural anodised, 90 degrees, Bar depth 5 mm, Bar height 18 mm, Bar spacing 12 mm, Free area, approx. 70 %
Suitable for: Width 190 mm
Suitable for: Width 190 mm
Article no.:
194000142519
Mitred corner
Roll-up grille Aluminium, natural anodised, other angles, Bar depth 5 mm, Bar height 18 mm, Bar spacing 12 mm, Free area, approx. 70 %
Suitable for: Width 190 mm
Suitable for: Width 190 mm
Article no.:
194000142619
Mitred corner
Linear grille Aluminium, natural anodised, 90 degrees, Bar depth 5 mm, Bar height 18 mm, Bar spacing 12 mm, Free area, approx. 70 %
Suitable for: Width 190 mm
Suitable for: Width 190 mm
Article no.:
194000142719
Mitred corner
Linear grille Aluminium, natural anodised, other angles, Bar depth 5 mm, Bar height 18 mm, Bar spacing 12 mm, Free area, approx. 70 %
Suitable for: Width 190 mm
Suitable for: Width 190 mm
Article no.:
194000142819
Installation covers
Installation cover
to protect trench during installation, factory-fitted, grilles are packed separately
price per m
Suitable for: Width 190 mm
price per m
Suitable for: Width 190 mm
Article no.:
194000100919
Downloads
Declarations/Certificates
Certificate ISO 50001:2018
PDF
(194 kB)
Certificate ISO 9001:2008
PDF
(118 kB)
Digital EPD database Katherm QK
EPD for Katherm QK
PDF
(2.7 MB)
UKCA Declaration Katherm HK, QK, QK nano
PDF
(468 kB)
Cross-product information
Products
PDF
(10.7 MB)
Information sheet trench heating BS EN 16430 UK version
PDF
(215 kB)
BIM data (Building Information Modeling)
Kampmann Group BIM data
Technical catalogues
Katherm QK, QK nano trench heating
PDF
(12.7 MB)
Manuals
Katherm QK, brief instructions
PDF
(4 MB)
Katherm QK trench heating
PDF
(5.1 MB)
Katherm QK - Wiring diagrams, control KaControl
PDF
(1.8 MB)
Katherm QK - Wiring Diagrams, electromechanical control
PDF
(1.2 MB)
CAD-Drawings
Katherm QK 190, PDF top view
PDF
(1.1 MB)
Katherm QK 190, PDF cross-sections
PDF
(88 kB)
Katherm QK 190, PDF front views
PDF
(131 kB)
Katherm QK 190, DWG top view
DWG
(3.8 MB)
Katherm QK 190, DWG cross-sections
DWG
(392 kB)
Katherm QK 190, DWG front views
DWG
(361 kB)
Installation plans
Katherm QK, electromechanical control
PDF