Trench Technology
LOGO_KAMPMANN_BLAU

Katherm QK nano

Article no.: 442170742235C1
Use the dropdown menus to quickly and simply adapt the figures to your requirements.
442170742235C1

Overview

Calculate performance data

Sound power octave spectrum

The sound power is determined depending on the use according to DIN EN ISO 3741 (in the echo chamber), according to DIN EN ISO 3744 (in the low-reflective half-space) or according to DIN EN ISO 9614 (intensity method).
Oktave Spektrum
EPD data

Item number-specific LCA data based on verified EPD according to EN 15804, which is available for download at The International EPD System. Separate subdivision of life cycle modules available online via button "EPD data sheet". The environmental impacts of module B refer to 1 year of operation. A: Product and construction process stage - B: Use stage - C: End of life stage - D: Benefits and loads beyond the system boundary

Impact Category A B C D
GWP - Fossil | kg CO₂ eq 5.15E+01 4.73E+00 3.16E+00 -2.65E+01
GWP - Biogenic | kg CO₂ eq 8.89E-02 6.76E-03 3.98E-04 -4.39E-02
GWP - Luluc | kg CO₂ eq 2.07E-01 2.76E-02 2.49E-04 -1.46E-01
GWP - Total | kg CO₂ eq 5.18E+01 4.75E+00 3.16E+00 -2.67E+01
ODP | kg CFC-11 eq 1.73E-06 2.08E-07 5.73E-08 -6.77E-07
AP | mol H+ eq 6.47E-01 5.02E-02 1.42E-03 -4.14E-01
EP - Freshwater | kg P eq 5.49E-02 3.68E-03 6.46E-05 -3.46E-02
EP - Marine | kg N eq 1.25E-01 1.13E-02 4.84E-04 -3.47E-02
EP - Terrestrial | mol N eq 7.51E-01 6.23E-02 4.94E-03 -4.13E-01
POCP | kg NMVOC 2.82E-01 1.82E-02 1.60E-03 -1.64E-01
ADPE | kg Sb eq 5.90E-03 5.21E-04 1.18E-06 -4.25E-03
ADPF | MJ 6.74E+02 1.08E+02 3.35E+00 -3.25E+02
WDP | m³ depriv. 1.41E+01 7.97E-01 1.36E-01 -6.00E+00
PM | disease inc. 4.21E-06 1.90E-07 2.11E-08 -2.16E-06
IR | kBq U-235 eq 5.26E+00 3.46E+00 1.55E-02 -2.18E+00
ETP - FW | CTUe 1.00E+03 8.78E+01 2.43E+01 -4.61E+02
HTP - C | CTUh 2.61E-07 9.67E-09 5.19E-10 -1.47E-07
HTP - NC | CTUh 6.44E-06 5.34E-07 5.84E-09 -4.50E-06
SQP | Pt 4.51E+02 5.97E+01 3.39E+00 -1.38E+02
PERE | MJ 1.18E+02 2.45E+01 1.93E-01 -5.22E+01
PERM | MJ 0.00E+00 0.00E+00 0.00E+00 0.00E+00
PERT | MJ 1.18E+02 2.45E+01 1.93E-01 -5.22E+01
PENRE | MJ 6.74E+02 1.08E+02 3.35E+00 -3.25E+02
PENRM | MJ 0.00E+00 0.00E+00 0.00E+00 0.00E+00
PENRT | MJ 6.74E+02 1.08E+02 3.35E+00 -3.25E+02
SM | kg 0.00E+00 0.00E+00 0.00E+00 0.00E+00
RSF | MJ 0.00E+00 0.00E+00 0.00E+00 0.00E+00
NRSF | MJ 0.00E+00 0.00E+00 0.00E+00 0.00E+00
FW | m³ 5.18E-01 5.83E-02 3.49E-03 -2.06E-01
HWD | kg 0.00E+00 0.00E+00 0.00E+00 0.00E+00
NHWD | kg 3.30E+00 0.00E+00 0.00E+00 0.00E+00
RWD | kg 0.00E+00 0.00E+00 0.00E+00 0.00E+00
CRU | kg 0.00E+00 0.00E+00 0.00E+00 0.00E+00
MFR | kg 0.00E+00 0.00E+00 1.01E+01 0.00E+00
MER | kg 0.00E+00 0.00E+00 1.21E+00 0.00E+00
EE (Electrical) | MJ 0.00E+00 0.00E+00 0.00E+00 0.00E+00
EE (Thermal) | MJ 0.00E+00 0.00E+00 0.00E+00 0.00E+00
*GWP-GHG | kg CO₂ eq 5.19E+01 4.77E+00 3.16E+00 -2.67E+01

Product has been added

view wish list
To create wish lists, you have to log in or re-register .
Add to my wishlist

Accessories

Control accessories KaControl
KaController

KaController

with one-button operation, 24 V wall-mounted room control unit, with integral room temperature sensor, Protection class IP 30, Temperature setting range 8 - 35 °C, Colour similar to RAL 9010 pure white, made of resistant PVC, Type 3210001

Suitable for: all units with control option KaControl -C1
Article no.: 196003210001

Product has been added

view wish list
To create wish lists, you have to log in or re-register .
Add to my wishlist
Details
KaController

KaController

with one-button operation, 24 V wall-mounted room control unit, with integral room temperature sensor, Protection class IP 30, Temperature setting range 8 - 35 °C, Colour similar to RAL 9017 traffic black, made of resistant PVC, Type 3210006

Suitable for: all units with control option KaControl -C1
Article no.: 196003210006

Product has been added

view wish list
To create wish lists, you have to log in or re-register .
Add to my wishlist
Details
KaController

KaController

with side operating keys, 24 V wall-mounted room control unit, with integral room temperature sensor, Protection class IP 30, Temperature setting range 8 - 35 °C, Colour similar to RAL 9010 pure white, made of resistant PVC, Type 3210002

Suitable for: all units with control option KaControl -C1
Article no.: 196003210002

Product has been added

view wish list
To create wish lists, you have to log in or re-register .
Add to my wishlist
Details
Room temperature sensor

Room temperature sensor

Wall-mounted, Surface-mounted, Protection class IP 30, Colour similar to RAL 9010 pure white, made of plastic, Type 3250110
Is the KaController installation site suitable for a temperature measurement? - If it is not suitable, e.g. behind a curtain, then a KaControl room temperature sensor should be chosen for each group!

Suitable for: all units with KaControl -C1 and climate controller art. no. 19600014894*
Article no.: 196003250110

Product has been added

view wish list
To create wish lists, you have to log in or re-register .
Add to my wishlist
Details
Serial KNX card

Serial KNX card

for integration into a KNX/EIB network, interface PCOS00KXN0, Type 3260702
The communication card slots into the free interface on the PCB.

Suitable for: all units with control option KaControl -C1
Article no.: 196003260702

Product has been added

view wish list
To create wish lists, you have to log in or re-register .
Add to my wishlist
Details
Serial CANbus card

Serial CANbus card

to increase the number of units in a single-circuit system from 7 to a maximum of 30 units, one required per unit, Extension of the cable length from the first to the last unit from 30 m to 500 m, Can only be used with the KaControl -C1 control version!The room temperature cannot be recorded by a room sensor when using CanBus cards., Type 3260301

Suitable for: all units with control option KaControl -C1
Article no.: 196003260301

Product has been added

view wish list
To create wish lists, you have to log in or re-register .
Add to my wishlist
Details
Serial Modbus card

Serial Modbus card

Type 3260101
Required for each device for connection to KaControl panels or on-site Modbus networks.
The communication card slots into the free interface on the PCB.

Suitable for: all units with control option KaControl -C1
Article no.: 196003260101

Product has been added

view wish list
To create wish lists, you have to log in or re-register .
Add to my wishlist
Details
Valve kits
Valve kit

Valve kit

with pre-settable valve body, return shut-off valve and matching spacer, 24 V actuator, kvs value 1 m³/h, Max. operating pressure 10 bar

Suitable for: DN 15
Article no.: 194000442100

Product has been added

view wish list
To create wish lists, you have to log in or re-register .
Add to my wishlist
Details
Connection accessories
Connection set

Connection set

with two return shut-off valves and matching adapter; when using the Katherm QK nano with a central manifold

Article no.: 194000442101

Product has been added

view wish list
To create wish lists, you have to log in or re-register .
Add to my wishlist
Details
Installation covers
Installation cover

Installation cover

to protect trench during installation, factory-fitted, grilles are packed separately
price per m

Suitable for: Width 165 mm
Article no.: 194000101916

Product has been added

view wish list
To create wish lists, you have to log in or re-register .
Add to my wishlist
Details

Downloads

Declarations/Certificates
Certificate ISO 50001:2018
PDF (194 kB)
Certificate ISO 9001:2008
PDF (118 kB)
Digital EPD database Katherm QK nano
EPD Katherm QK nano
PDF (9.3 MB)
UKCA Declaration Katherm HK, QK, QK nano
PDF (468 kB)
Cross-product information
Products
PDF (10.7 MB)
Information sheet trench heating BS EN 16430 UK version
PDF (215 kB)
BIM data (Building Information Modeling)
Kampmann Group BIM data
Technical catalogues
Katherm QK, QK nano trench heating
PDF (12.7 MB)
Manuals
Katherm QK nano trench heating
PDF (9.7 MB)
Installation plans
Katherm QK nano, KaControl version
PDF (801 kB)
CAD-Drawings
Katherm QK nano, trench length 2000 mm, electromechanical control or KaControl, cross-sections, views
PDF (122 kB)
Katherm QK nano, trench length 2000 mm, electromechanical control or KaControl, cross-sections, views
DWG (413 kB)
Katherm QK nano, trench length 2000 mm, electromechanical control or KaControl, cross-sections, views
DXF (1.6 MB)