Trench Technology
Katherm QK nano
Article no.:
442170742227C1
Overview
- KaControl control system for operation via a separate room control unit, external control via a 0-10 V signal or building automation systems, such as KNX, modbus, BACnet (additional plug-in card accessory required)
- Room control of up to six units or up to 30 units with CANbus cards that are additionally required
- Demand-led automatic fan or optional manual fan control
- Connection options, including external room sensor, window contact etc.
- Individually parametrisable for optimum adaptation to the situation on site
The KaControl control option provides the option of omitting the valve control data point when externally controlled by an on-site 0-10 V signal. The fan valve and speed control logic comes from the KaControl. Note the deviation of the signal points from the design program with 0-10 V control by others.
Design program data: 2 V 4 V 6 V 8 V 10 V
External 0-10 V on the KaControl: 4.3 V 5.5 V 6.8 V 7.8 V 10 V
The Eurokonus valve connection enables the Katherm QK nano to be quickly and easily installed on site. In addition, height adjustment feet and raised floor height adjustment feet are supplied as standard to further reduce the installation time and thus the cost.
- 24 V electromechanical
- 230 V electromechanical including power unit and terminal block or KaControl incl. power unit, PCB and connection box
- For valves and electrical components
- With cover for visual protection and to protect against dirt
- Prevents damage to the convector when installing the valves or threaded connectors
- For the simple fixing of the floor trench
- With rubber underlay for acoustic decoupling
Calculate performance data
Sound power octave spectrum
The sound power is determined depending on the use according to DIN EN ISO 3741 (in the echo chamber), according to DIN EN ISO 3744 (in the low-reflective half-space) or according to DIN EN ISO 9614 (intensity method).
Oktave Spektrum
EPD data
Item number-specific LCA data based on verified EPD according to EN 15804, which is available for download at The International EPD System. Separate subdivision of life cycle modules available online via button "EPD data sheet". The environmental impacts of module B refer to 1 year of operation. A: Product and construction process stage - B: Use stage - C: End of life stage - D: Benefits and loads beyond the system boundary
Impact Category | A | B | C | D |
---|---|---|---|---|
GWP - Fossil | kg CO₂ eq | 4.04E+01 | 3.71E+00 | 2.48E+00 | -2.08E+01 |
GWP - Biogenic | kg CO₂ eq | 6.98E-02 | 5.31E-03 | 3.12E-04 | -3.45E-02 |
GWP - Luluc | kg CO₂ eq | 1.63E-01 | 2.16E-02 | 1.96E-04 | -1.14E-01 |
GWP - Total | kg CO₂ eq | 4.06E+01 | 3.73E+00 | 2.48E+00 | -2.10E+01 |
ODP | kg CFC-11 eq | 1.36E-06 | 1.63E-07 | 4.49E-08 | -5.31E-07 |
AP | mol H+ eq | 5.08E-01 | 3.94E-02 | 1.11E-03 | -3.25E-01 |
EP - Freshwater | kg P eq | 4.31E-02 | 2.89E-03 | 5.07E-05 | -2.71E-02 |
EP - Marine | kg N eq | 9.81E-02 | 8.87E-03 | 3.80E-04 | -2.72E-02 |
EP - Terrestrial | mol N eq | 5.90E-01 | 4.89E-02 | 3.88E-03 | -3.24E-01 |
POCP | kg NMVOC | 2.21E-01 | 1.43E-02 | 1.25E-03 | -1.29E-01 |
ADPE | kg Sb eq | 4.63E-03 | 4.09E-04 | 9.28E-07 | -3.34E-03 |
ADPF | MJ | 5.29E+02 | 8.51E+01 | 2.63E+00 | -2.55E+02 |
WDP | m³ depriv. | 1.11E+01 | 6.25E-01 | 1.07E-01 | -4.70E+00 |
PM | disease inc. | 3.30E-06 | 1.49E-07 | 1.66E-08 | -1.70E-06 |
IR | kBq U-235 eq | 4.13E+00 | 2.71E+00 | 1.22E-02 | -1.71E+00 |
ETP - FW | CTUe | 7.85E+02 | 6.89E+01 | 1.90E+01 | -3.62E+02 |
HTP - C | CTUh | 2.05E-07 | 7.59E-09 | 4.07E-10 | -1.15E-07 |
HTP - NC | CTUh | 5.05E-06 | 4.19E-07 | 4.58E-09 | -3.53E-06 |
SQP | Pt | 3.54E+02 | 4.68E+01 | 2.66E+00 | -1.08E+02 |
PERE | MJ | 9.29E+01 | 1.93E+01 | 1.51E-01 | -4.10E+01 |
PERM | MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
PERT | MJ | 9.29E+01 | 1.93E+01 | 1.51E-01 | -4.10E+01 |
PENRE | MJ | 5.29E+02 | 8.51E+01 | 2.63E+00 | -2.55E+02 |
PENRM | MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
PENRT | MJ | 5.29E+02 | 8.51E+01 | 2.63E+00 | -2.55E+02 |
SM | kg | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
RSF | MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
NRSF | MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
FW | m³ | 4.07E-01 | 4.57E-02 | 2.74E-03 | -1.62E-01 |
HWD | kg | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
NHWD | kg | 2.59E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
RWD | kg | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
CRU | kg | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
MFR | kg | 0.00E+00 | 0.00E+00 | 7.95E+00 | 0.00E+00 |
MER | kg | 0.00E+00 | 0.00E+00 | 9.47E-01 | 0.00E+00 |
EE (Electrical) | MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
EE (Thermal) | MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
*GWP-GHG | kg CO₂ eq | 4.07E+01 | 3.74E+00 | 2.48E+00 | -2.10E+01 |
Accessories
Control accessories KaControl
KaController
with one-button operation, 24 V wall-mounted room control unit, with integral room temperature sensor, Protection class IP 30, Temperature setting range 8 - 35 °C, Colour similar to RAL 9010 pure white, made of resistant PVC, Type 3210001
Suitable for: all units with control option KaControl -C1
Suitable for: all units with control option KaControl -C1
Article no.:
196003210001
KaController
with one-button operation, 24 V wall-mounted room control unit, with integral room temperature sensor, Protection class IP 30, Temperature setting range 8 - 35 °C, Colour similar to RAL 9017 traffic black, made of resistant PVC, Type 3210006
Suitable for: all units with control option KaControl -C1
Suitable for: all units with control option KaControl -C1
Article no.:
196003210006
KaController
with side operating keys, 24 V wall-mounted room control unit, with integral room temperature sensor, Protection class IP 30, Temperature setting range 8 - 35 °C, Colour similar to RAL 9010 pure white, made of resistant PVC, Type 3210002
Suitable for: all units with control option KaControl -C1
Suitable for: all units with control option KaControl -C1
Article no.:
196003210002
Room temperature sensor
Wall-mounted, Surface-mounted, Protection class IP 30, Colour similar to RAL 9010 pure white, made of plastic, Type 3250110
Is the KaController installation site suitable for a temperature measurement? - If it is not suitable, e.g. behind a curtain, then a KaControl room temperature sensor should be chosen for each group!
Suitable for: all units with KaControl -C1 and climate controller art. no. 19600014894*
Is the KaController installation site suitable for a temperature measurement? - If it is not suitable, e.g. behind a curtain, then a KaControl room temperature sensor should be chosen for each group!
Suitable for: all units with KaControl -C1 and climate controller art. no. 19600014894*
Article no.:
196003250110
Serial KNX card
for integration into a KNX/EIB network, interface PCOS00KXN0, Type 3260702
The communication card slots into the free interface on the PCB.
Suitable for: all units with control option KaControl -C1
The communication card slots into the free interface on the PCB.
Suitable for: all units with control option KaControl -C1
Article no.:
196003260702
Serial CANbus card
to increase the number of units in a single-circuit system from 7 to a maximum of 30 units, one required per unit, Extension of the cable length from the first to the last unit from 30 m to 500 m, Can only be used with the KaControl -C1 control version!The room temperature cannot be recorded by a room sensor when using CanBus cards., Type 3260301
Suitable for: all units with control option KaControl -C1
Suitable for: all units with control option KaControl -C1
Article no.:
196003260301
Serial Modbus card
Type 3260101
Required for each device for connection to KaControl panels or on-site Modbus networks.
The communication card slots into the free interface on the PCB.
Suitable for: all units with control option KaControl -C1
Required for each device for connection to KaControl panels or on-site Modbus networks.
The communication card slots into the free interface on the PCB.
Suitable for: all units with control option KaControl -C1
Article no.:
196003260101
Valve kits
Valve kit
with pre-settable valve body, return shut-off valve and matching spacer, 24 V actuator, kvs value 1 m³/h, Max. operating pressure 10 bar
Suitable for: DN 15
Suitable for: DN 15
Article no.:
194000442100
Connection accessories
Connection set
with two return shut-off valves and matching adapter; when using the Katherm QK nano with a central manifold
Article no.:
194000442101
Installation covers
Installation cover
to protect trench during installation, factory-fitted, grilles are packed separately
price per m
Suitable for: Width 165 mm
price per m
Suitable for: Width 165 mm
Article no.:
194000101916
Downloads
Declarations/Certificates
Certificate ISO 50001:2018
PDF
(194 kB)
Certificate ISO 9001:2008
PDF
(118 kB)
Digital EPD database Katherm QK nano
EPD Katherm QK nano
PDF
(9.3 MB)
UKCA Declaration Katherm HK, QK, QK nano
PDF
(468 kB)
Cross-product information
Products
PDF
(10.7 MB)
Information sheet trench heating BS EN 16430 UK version
PDF
(215 kB)
BIM data (Building Information Modeling)
Kampmann Group BIM data
Technical catalogues
Katherm QK, QK nano trench heating
PDF
(12.7 MB)
Manuals
Katherm QK nano trench heating
PDF
(9.7 MB)
Installation plans
Katherm QK nano, KaControl version
PDF
(801 kB)
CAD-Drawings
Katherm QK nano, trench length 1600 mm, electromechanical control or KaControl, cross-sections, views
PDF
(113 kB)
Katherm QK nano, trench length 1600 mm, electromechanical control or KaControl, cross-sections, views
DXF
(1.5 MB)
Katherm QK nano, trench length 1600 mm, electromechanical control or KaControl, cross-sections, views
DWG
(379 kB)