Trench Technology
Katherm HK
Article no.:
14332231321900
Overview
- All the installed components are centrally arranged on a terminal block
- Electric connection unit is positioned for ease of access
- Built-in 230 V/24 V power supply unit
- Control by Kampmann room thermostats or on-site controls
- Option to wire through to the next unit
Katherm HK units with supply air function are perfectly suited to supply primary air (fresh air) into a space, seamlessly combining heating, cooling and a supply of fresh air. There are two versions available: primary air intake via supply air modules or through supply air trenches. In both versions, the primary air volume flow exits the trench at a minimal and low-turbulence air discharge speed. The volume of air supplied can be adjusted as required by means of air sliders.
- Energy-saving, with flow-optimised impellers, cascaded arrangement as a continuous fan belt
- Easily removeable, plug & play fan
- Even air flow through convector
- Robust and whisper-quiet motor design
- Continuously variable control via external 0-10 V signal
- With anti-torsion device
- Made of the proven copper/aluminium combination, optimised for air flow and output
- Optionally available with projecting connections
- Painted graphite-grey
- Act as a finger guard for the tangential fan, filter frame, airflow baffle, grille seat and reinforcing stay to strengthen the trench
- In a 2-pipe version for additional electric heating
- With integral, continuously variably controllable electric heating coil
- With built-in safety chain consisting of 2 safety temperature switches
- Sustainable 4-pipe system solution at the cost of a 2-pipe system
- Easy removal of tangential fan without tool
- Novl coupling/cone pin system
- Simultaneous sound decoupling
- For fast and safe wiring, saves installation time
Calculate performance data
Sound power octave spectrum
The sound power is determined depending on the use according to DIN EN ISO 3741 (in the echo chamber), according to DIN EN ISO 3744 (in the low-reflective half-space) or according to DIN EN ISO 9614 (intensity method).
Oktave Spektrum
EPD data
Item number-specific LCA data based on verified EPD according to EN 15804, which is available for download at The International EPD System. Separate subdivision of life cycle modules available online via button "EPD data sheet". The environmental impacts of module B refer to 1 year of operation. A: Product and construction process stage - B: Use stage - C: End of life stage - D: Benefits and loads beyond the system boundary
Impact Category | A | B | C | D |
---|---|---|---|---|
GWP - Fossil | kg CO₂ eq | 9.63E+01 | 6.04E+00 | 3.46E+00 | -3.94E+01 |
GWP - Biogenic | kg CO₂ eq | -2.44E+00 | 7.05E-01 | 1.36E-03 | -1.92E-02 |
GWP - Luluc | kg CO₂ eq | 4.21E-01 | 2.33E-02 | 1.70E-04 | -2.86E-01 |
GWP - Total | kg CO₂ eq | 9.43E+01 | 6.76E+00 | 3.46E+00 | -3.99E+01 |
ODP | kg CFC-11 eq | 5.40E-06 | 4.07E-07 | 6.81E-08 | -2.66E-06 |
AP | mol H+ eq | 1.01E+00 | 4.89E-02 | 1.41E-03 | -5.78E-01 |
EP - Freshwater | kg P eq | 8.42E-02 | 4.16E-03 | 4.46E-05 | -4.79E-02 |
EP - Marine | kg N eq | 1.12E-01 | 5.72E-03 | 4.77E-04 | -4.93E-02 |
EP - Terrestrial | mol N eq | 1.24E+00 | 6.76E-02 | 5.48E-03 | -5.73E-01 |
POCP | kg NMVOC | 3.68E-01 | 1.69E-02 | 1.20E-03 | -1.66E-01 |
ADPE | kg Sb eq | 1.45E-02 | 1.39E-03 | 1.07E-06 | -1.10E-02 |
ADPF | MJ | 1.20E+03 | 1.49E+02 | 3.53E+00 | -4.86E+02 |
WDP | m³ depriv. | 2.76E+01 | 9.63E-01 | 1.08E-01 | -8.55E+00 |
PM | disease inc. | 7.39E-06 | 1.76E-07 | 2.14E-08 | -3.00E-06 |
IR | kBq U-235 eq | 9.98E+00 | 4.93E+00 | 2.05E-02 | -4.20E+00 |
ETP - FW | CTUe | 6.04E+03 | 3.29E+02 | 1.44E+01 | -4.23E+03 |
HTP - C | CTUh | 5.63E-07 | 1.15E-08 | 4.57E-10 | -2.25E-07 |
HTP - NC | CTUh | 9.75E-06 | 4.76E-07 | 7.34E-09 | -6.60E-06 |
SQP | Pt | 8.14E+02 | 6.61E+01 | 5.02E+00 | -2.31E+02 |
PERE | MJ | 2.81E+02 | 2.77E+01 | 1.15E-01 | -9.31E+01 |
PERM | MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
PERT | MJ | 2.81E+02 | 2.77E+01 | 1.15E-01 | -9.31E+01 |
PENRE | MJ | 1.20E+03 | 1.49E+02 | 3.53E+00 | -4.86E+02 |
PENRM | MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
PENRT | MJ | 1.20E+03 | 1.49E+02 | 3.53E+00 | -4.86E+02 |
SM | kg | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
RSF | MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
NRSF | MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
FW | m³ | 5.76E-01 | 6.03E-02 | 4.44E-03 | -2.70E-01 |
HWD | kg | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
NHWD | kg | 4.83E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
RWD | kg | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
CRU | kg | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
MFR | kg | 0.00E+00 | 0.00E+00 | 1.47E+01 | 0.00E+00 |
MER | kg | 0.00E+00 | 0.00E+00 | 1.16E+00 | 0.00E+00 |
EE (Electrical) | MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
EE (Thermal) | MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
*GWP-GHG | kg CO₂ eq | 9.47E+01 | 5.99E+00 | 3.46E+00 | -3.83E+01 |
Accessories
Control accessories electromechanical 230 V
Room thermostat
Heating/Cooling, 2- and 4-pipe, 3-stage. Only in conjunction with valves/valve kits with actuator, with OFF/Manual/Automatic fan switchover, 230 V AC, Open/Closed, Surface-mounted, Protection class II, Protection class IP 30, Temperature setting range 5 - 30 °C, Colour similar to RAL 9010 pure white, Type 30155
optional connectible, remote sensor art. no. 196000148921
can optionally be connected, clip-on sensor art. no. 196000148922
Suitable for: EC units electromechanical, 5 Katherm HK Trench Technology, 5 TOP, Ultra or Ultra Allround Unit Heaters, 5 Venkon or PowerKon LT Fan Coils, 5 KaCool D AF, KaCool W or KaDeck Fan Coils
optional connectible, remote sensor art. no. 196000148921
can optionally be connected, clip-on sensor art. no. 196000148922
Suitable for: EC units electromechanical, 5 Katherm HK Trench Technology, 5 TOP, Ultra or Ultra Allround Unit Heaters, 5 Venkon or PowerKon LT Fan Coils, 5 KaCool D AF, KaCool W or KaDeck Fan Coils
Article no.:
196000030155
Climate Controller
Heating/Cooling, 2- and 4-pipe, Without Modbus, only with valves/valve kits, continuously variable, with LCD operating menu and integrated timer program, 230 V AC, Open/Closed, Surface-mounted, Protection class IP 30, Temperature setting range 0 - 50 °C, Colour similar to RAL 9010 pure white, Type 148941
Suitable for: EC units electromechanical, 4 Katherm HK Trench Technology, 4 KaCool D AF, KaCool W, Venkon or KaDeck Fan Coils, 4 Ultra Allround Unit Heaters
Suitable for: EC units electromechanical, 4 Katherm HK Trench Technology, 4 KaCool D AF, KaCool W, Venkon or KaDeck Fan Coils, 4 Ultra Allround Unit Heaters
Article no.:
196000148941
Climate Controller
Heating/Cooling, 2- and 4-pipe, Without Modbus, only with valves/valve kits, continuously variable, with LCD operating menu and integrated timer program, 230 V AC, Open/Closed, Surface-mounted, Protection class IP 30, Temperature setting range 0 - 50 °C, Colour similar to RAL 9004 signal black, Type 148942
Suitable for: EC units electromechanical, 4 Katherm HK Trench Technology, 4 KaCool D AF, KaCool W, Venkon or KaDeck Fan Coils, 4 Ultra Allround Unit Heaters
Suitable for: EC units electromechanical, 4 Katherm HK Trench Technology, 4 KaCool D AF, KaCool W, Venkon or KaDeck Fan Coils, 4 Ultra Allround Unit Heaters
Article no.:
196000148942
Climate Controller
Heating/Cooling, 2- and 4-pipe, with Modbus, only with valves/valve kits, continuously variable, with LCD operating menu and integrated timer program, 230 V AC, Open/Closed, Surface-mounted, Protection class IP 30, Temperature setting range 0 - 50 °C, Colour similar to RAL 9010 pure white, Type 148943
Suitable for: EC units electromechanical, 4 Katherm HK Trench Technology, 4 KaCool D AF, KaCool W, Venkon or KaDeck Fan Coils, 4 Ultra Allround Unit Heaters
Suitable for: EC units electromechanical, 4 Katherm HK Trench Technology, 4 KaCool D AF, KaCool W, Venkon or KaDeck Fan Coils, 4 Ultra Allround Unit Heaters
Article no.:
196000148943
Climate Controller
Heating/Cooling, 2- and 4-pipe, with Modbus, only with valves/valve kits, continuously variable, with LCD operating menu and integrated timer program, 230 V AC, Open/Closed, Surface-mounted, Protection class IP 30, Temperature setting range 0 - 50 °C, Colour similar to RAL 9004 signal black, Type 148944
Suitable for: EC units electromechanical, 4 Katherm HK Trench Technology, 4 KaCool D AF, KaCool W, Venkon or KaDeck Fan Coils, 4 Ultra Allround Unit Heaters
Suitable for: EC units electromechanical, 4 Katherm HK Trench Technology, 4 KaCool D AF, KaCool W, Venkon or KaDeck Fan Coils, 4 Ultra Allround Unit Heaters
Article no.:
196000148944
Valve kits
Valve kit
Heating/Cooling, 2-pipe, includes pre-adjustable valve, angled return shut-off valve, with an axial valve, pre-adjustable, and an angled return shut-off valve, 24 V actuator, Connection 1/2'', kvs value 1 m³/h, Max. operating pressure 10 bar, supplied separately
Suitable for: DN 15
Suitable for: DN 15
Article no.:
194000143211
Valve kit
Heating/Cooling, 2-pipe, 1 pre-adjustable valve, actuator, angled return shut-off valve, 24 V actuator, with an axial valve, pre-adjustable, and an angled return shut-off valve, Connection 1/2'', kvs value 2.65 m³/h, Max. operating pressure 16 bar, supplied separately
Suitable for: for higher flow from 250 l/h, DN 15
Suitable for: for higher flow from 250 l/h, DN 15
Article no.:
194000143241
Valves and return shut-off valves
Valve body
Axial, pre-settable, Connection 1/2'', kvs value 1 m³/h, Max. operating pressure 10 bar
Suitable for: Katherm NK 137/182 (trench heights 92 mm and 120 mm), DN 15
Suitable for: Katherm NK 137/182 (trench heights 92 mm and 120 mm), DN 15
Article no.:
194000346911
Valve body
Axial, pre-settable, Connection 1/2'', kvs value 2.65 m³/h, Max. operating pressure 16 bar
Suitable for: for higher flow from 250 l/h, DN 15
Suitable for: for higher flow from 250 l/h, DN 15
Article no.:
194000346914
Pre-setting key
Once per project necessary.
Suitable for: pre-settable valve bodies, valve kits and convector connection kit
Suitable for: pre-settable valve bodies, valve kits and convector connection kit
Article no.:
194000346915
Pre-setting set
Suitable for: pre-settable valve bodies and valve kits with higher flow from 250 l/h
Article no.:
194000346916
Return shut-off valve
Straight, Connection 1/2''
Article no.:
194000145952
Return shut-off valve
Straight, Connection 1/2''
Suitable for: for higher flow from 250 l/h
Suitable for: for higher flow from 250 l/h
Article no.:
194000145954
Return shut-off valve
angled, Connection 1/2''
Suitable for: for higher flow from 250 l/h
Suitable for: for higher flow from 250 l/h
Article no.:
194000145955
Valve actuators
Thermoelectric actuator
230 V AC
Suitable for: room thermostat type 30155 and climate controller type 14894x
Suitable for: room thermostat type 30155 and climate controller type 14894x
Article no.:
194000146905
Thermoelectric actuator
24 V AC/DC
Suitable for: Katherm, control configuration KaControl -C1 and clock thermostat type 30456
Suitable for: Katherm, control configuration KaControl -C1 and clock thermostat type 30456
Article no.:
194000146906
Filter
Filter for air inlet
Replacement filter without frame, ISO Coarse 30% filter (G2)
Suitable for: Length 1200 mm
Suitable for: Length 1200 mm
Article no.:
143014313019
Condensate tray/pump
Connection kit for condensation pump
230 V 50 Hz, 20 W, supplied separately, Type 143813
Suitable for: width 320 mm, height 130 mm and width 360 mm, height 210 mm
Suitable for: width 320 mm, height 130 mm and width 360 mm, height 210 mm
Article no.:
194000143813
Connection kit for condensation pump
230 V 50 Hz, 20 W, factory-fitted, Type 143814
Suitable for: width 320 mm, height 130 mm and width 360 mm, height 210 mm
Suitable for: width 320 mm, height 130 mm and width 360 mm, height 210 mm
Article no.:
194000143814
Installation covers
Installation cover
to protect trench during installation, factory-fitted, grilles are packed separately
price per m
price per m
Article no.:
194000100320
Downloads
Declarations/Certificates
Certificate ISO 50001:2018
PDF
(194 kB)
Certificate ISO 9001:2008
PDF
(118 kB)
Digital EPD database Katherm HK E
Digital EPD database Katherm HK
EPD Katherm HK E
PDF
(1.6 MB)
EPD Katherm HK
PDF
(2.5 MB)
UKCA Declaration Katherm HK, QK, QK nano
PDF
(468 kB)
Cross-product information
Products
PDF
(10.7 MB)
Information sheet trench heating BS EN 16430 UK version
PDF
(215 kB)
Manuals
Katherm HK trench heating
PDF
(7.7 MB)
Katherm HK, brief instructions
PDF
(3.8 MB)
BIM data (Building Information Modeling)
Kampmann Group BIM data
Technical catalogues
Katherm HK trench heating
PDF
(13.1 MB)
CAD-Drawings
Katherm HK, trench width 320 mm, 2-pipe system, views
PDF
(122 kB)
Katherm HK, trench width 320 mm, 2-pipe system, top views
PDF
(145 kB)
Katherm HK, trench width 320 mm, 2-pipe system, views
DWG
(263 kB)
Katherm HK, trench width 320 mm, 2-pipe system, views
DXF
(1.9 MB)
Katherm HK, trench width 320 mm, 2-pipe system, top views
DWG
(535 kB)
Katherm HK, trench width 320 mm, 2-pipe system, top views
DXF
(3.9 MB)